Maxims and Instructions for the Boiler Room Useful to Engineers, Firemen & Mechanics; Relating to Steam Generators, Pumps, Appliances, Steam Heating, Practical Plumbing, etc.
Note 2.—In considering the stress or strain upon the expanded
or riveted over ends of a set of boiler tubes, it may be remembered
that the strain to be provided against is only that coming upon tube
plate, exposed to pressure, between the tube ends—the space occupied
by the tubes has no strain upon it.
The gauge to be employed by inspectors to determine the thickness of
boiler plates will be any standard American gauge furnished by the
Treasury Department.
All samples intended to be tested on the Riehle, Fairbanks, Olson, or
other reliable testing machine, must be prepared in form according to
the following diagram, viz.: eight inches in length, two inches in
width, cut out their centres as indicated.
Fig. E.
Portions of the Marine Boiler which Become Thin by Wear.
These are generally situated, 1st, at or a little above the line of
fire bars in the furnace; 2d, the ash pits; 3d, combustion chamber
backs; 4th, shell at water line; 5th, front and bottom of boiler.
The thinning can usually be detected by examination, sounding with a
round nosed hammer, or drilling small holes in suspected parts not
otherwise accessible for examination.
EXAMPLES OF CONSTRUCTION AND DRAWING
d
t
d
t
9⁄16″
1⁄4″
15⁄16″
5⁄8″
11⁄16″
5⁄16″
11⁄16″
3⁄4″
3⁄4″
3⁄8″
11⁄8″
7⁄8
7⁄8″
1⁄2″
13⁄16″
1″
d = DIAM. OF RIVET.
t = THICKNESS OF PLATE.
The small table above is of use in this and the four succeeding
pages; in all places in the drawings where “d” is used it indicates
the diameter of the rivet; “t” means the thickness of the plate;
“p” stands for pitch. The table also shows the proportion of rivet to
the plate—thus, a 1⁄4-inch plate requires a 9⁄16 rivet, etc.
It is recommended, in view of the increased disposition on the part of
official examiners to test the applicant’s knowledge of drawing, for
any one interested, to redraw to a full size all the rivets, plates,
and methods of joining the two contained on pages 113-116.
Fig. 53.Fig. 54.
The figures 53 to 60 will be understood without much explanation.
In figures 53 and 54the cup head, the conical head and pan head
rivets are shown.
Figs. 55 and 56 exhibit the details (and drawings) of single and double
riveting. Where the cut reads p = (21⁄2)d, it means that the distance
from the centre of one rivet to the centre of the next shall be 21⁄2
the diameter of the rivet, see example, page 115.
Fig. 55.Fig. 56.
Example.
If the size of the rivet used is 7⁄8ths, then 7⁄8 × 21⁄2 = 22⁄10
inches nearly, and this gives the proportionate strength of the plate
and the rivet, see page 113.
Fig. 57.
Figs. 57, 58, 59 and 60 show quite clearly the joints and rivet work
done in locomotive and marine work. Fig. 60 shows method of riveting 3
plates, A, B, and C, together.
Fig. 58.Fig. 59.Fig. 60.
RULE FOR SAFE INTERNAL PRESSURE
The safe internal pressure on cylindrical shells is found according to
the following rule, which has been adopted by the United States Board
of Supervising Inspectors, and any boiler shell not found in the tables
can be determined by this rule.
Rule.—Multiply one-sixth of the lowest tensile strength
found stamped on any plate in the cylindrical shell by the
thickness—expressed in inches or parts of an inch—of the thinnest
plate in the same cylindrical shell, and divide by the radius or half
diameter—also expressed in inches—and the result will be the pressure
allowable per square inch of surface for single riveting, to which add
twenty per centum for double riveting.
The hydrostatic pressure applied, under this table and rule, must be in
the proportion of one hundred and fifty pounds to the square inch, to
one hundred pounds to the square inch of the working pressure allowed.
Example.
What pressure should be allowed to be carried on a boiler 60″ diameter,
made of plates 3⁄8″ thick, having a tensile strength of 60,000 pounds?
Now then: