To find the weight of ball:

Rule.—Multiply the steam pressure by the area of the valve, and from the product subtract the effective weight of the valve and lever, then multiply the remainder by the distance from the valve centre to the fulcrum, and divide the product by the length of the lever.

Example.

 120pounds, steam pressure,
 8inches, area of valve,
 960 
 60pounds, weight of valve and lever,
 900 
 5inches, fulcrum,
Length of lever, 45 in. )4500 
 100pounds, weight of ball.

To find the length of lever:

Rule.—Multiply the steam pressure by the area of the valve, and from the product subtract the effective weight of the valve and lever, then multiply the remainder by the distance from the valve centre to the fulcrum, and divide the product by the weight of the ball.

Example.

 120pounds, steam pressure,
 8inches, area of valve,
 960 
 60pounds, weight of valve and lever,
 900 
 5 
100)4500(45 length of lever.

Every boiler should be provided with two safety valves, one of which should be put beyond the control of the attendant.

Safety valves that stick will do so even though tried every day, if they are simply lifted and dropped to the old place on the seat again. If a boiler should be found with an excessively high pressure, it would be one of the worst things to do to start the safety valve from its seat unless extra weight was added, for should the valve once start, it would so suddenly relieve the boiler of such a volume of steam as would cause a rush of water to the opening, and by a blow, just the same as in water hammer, rupture the boiler.

Such a condition is very possible to occur of itself when a safety valve sticks. The valve holds the pressure, that gets higher and higher, until so high that the safety valve does give way and allows so much steam to escape that the sudden changing of conditions sets the water in motion, and an explosion may result.

The noise made by a safety valve when it is blowing off may be regarded in two ways. First, by it is known that the valve is capable of performing its proper function, and that there is, therefore, a reasonable assurance that no explosion will result from excessive pressure of steam or other gas, and on the other hand too much noise of this kind indicates wasted fuel.

The hole of the safety valve may be 2, 3 or 4 inches; that does not say that the area is 3.1416, 7.06 or 12.56 square inches, but the area is that which is inside of the joint. The valve opening may be, say 2 inches, but the circle of contact of valve to seat may be of an average diameter of 21⁄8 inches, if so, all the close calculations otherwise will not avail. In the first place, the area of 2 inches equals 3.1416; that of 21⁄8 diameter equals 3.5466, showing a difference of .4 square inches.

Note.

Very extended rules issued by the U. S. Government for calculating the safe working pressure, dimensions and proportions of the safety valves for marine boilers are reprinted in “Hawkins’ Calculations” for engineers.

When a safety valve is described as a “2 inch safety valve,” etc., it means that two inches is the diameter of the pipe; hence the following rule and examples for finding the area.

Rule for finding Area of Valve Opening.

Square the diameter of the opening and multiply the product by the decimal .7854.

Example.

What is the area of a three inch valve? Now then:

3 × 3 = 9 × .7854 = 7.06 square inches, Ans.

Note.—A shorter method of calculating by .7854 in larger sums is to multiply by 11 and divide by 14, for decimal .7855 = the fraction 11⁄14th. Note: .7854 is the area of a circular inch.

When valves rise from their seats under increasing steam pressure they do so by a constantly diminished ratio which has been carefully determined by experiment and reduced to the following table.

Pressure in Lbs.Rise of Valve.
121-36 
201-48 
351-54 
451-65 
501-86 
601-86 
701-132
801-168
901-168

The following useful table was prepared by the Novelty Iron Works, New York.

Boiler Pressure
in Lbs. Above the
Atmosphere
Area of Orifice
in Sq. In. for
Each Sq. Ft. of
Heating Surface.
    0.25.022794
    0.5  .021164
    1.    .018515
    2.    .014814
    3.    .012345
    4.    .010582
    5.    .009259
  10.    .005698
  20.    .003221
  30.    .002244
  40.    .001723
  50.    .001389
  60.    .001176
  70.    .001015
  80.    .000892
  90.    .000796
100.    .000719
150.    .000481
200.    .000364

FEED WATER HEATERS.

Fig. 97.

There are two forms of feed water heaters: (1) The closed heater, where the feed water passes through tubes, which are enclosed in a shell, through which the exhaust steam passes. (2) The open heater, in which the steam and water come into contact. In the latter the water is sprayed into a space, through which the exhaust steam passes, or is run over a number of inclined perforated copper plates, mingled with the exhaust steam.

The original feed water heater called a “pot heater,” consisted of a vessel so constructed that the feed water was sprayed through the exhaust steam into a globe formed tank, from the bottom of which the heated water was pumped into the boiler; its name was originally the “pot heater,” but as it was open to the air through the exhaust pipe, it was, with its successively improved forms called the open heater.

All the heat imparted to the feed water, before it enters the boiler, is so much saved, not only in the cost of fuel, but by the increased capacity of the boiler, as the fuel in the furnace will not have this duty to perform. There are two sources of waste heat which can be utilized for this purpose: the chimney gases and the exhaust steam. The gases escaping to the chimney after being reduced to the lowest possible temperature contain a considerable quantity of heat. This waste of heat energy may be largely saved by the device illustrated on page 186.

Fig. 98.

How much saving is obtained under any given condition is a question requiring for its solution a careful calculation of all of the conditions which have a bearing on the subject. Exhaust steam under atmospheric pressure only has a sensible temperature of 212 degrees, but exhaust steam contains also a large number of heat units which are given up when the steam is condensed into water; for this reason it might be thought possible to raise the temperature of the feed water a few degrees higher even than the sensible temperature of the exhaust steam. But this should not be expected, on account of the radiation of heat that would occur above that of the steam.

The steam which escapes from the exhaust pipe dissipates into the atmosphere or discharges into the condenser over nine tenths of the heat it contained when leaving the boiler. This can be best utilized by exhaust feed water heaters, for the use of live steam heaters represents no saving in fuel, as all the heat imparted to the feed water by their use comes directly from the boiler. The purpose for which they are used is to elevate the temperature of the feed water above the boiling point, so as to precipitate the sulphate of lime and other scale forming substances, and prevent them from entering the boiler. Neither does the heat in the feed water introduced by an injector represent saving, as it comes from the boiler and was generated by the fuel.

It is important to note these two statements: 1, That neither live steam feed water heaters, nor 2, injectors save the heat from the escaping steam.

It is also well to remember that it requires a pound of water to absorb 1.146 heat units, and that this quantity of heat is distributed through the whole quantity of water, and as a pound of steam is the same as a pound of water, it may be understood that at 212° each pound of exhaust steam contains 1,146 heat units; ten pounds of steam contain 11,460 heat units distributed through the mass, etc.: thus, to explain still further:

To evaporate water into steam, it must first be heated to the boiling point, and then sufficient heat still further added to change it from the liquid to the gaseous state, or steam. Take one pound of water at 32 degrees and heat it to the boiling point, it will have received 212° - 32° = 180 heat units. A heat unit being the amount of heat necessary to raise one pound of water through one degree at its greatest density. To convert it into steam after it has been raised to the boiling point, requires the addition of 966 heat units, which are called latent, as they cannot be detected by the thermometer. This makes 180 + 966 = 1146 heat units, which is the total heat contained in one pound of water made into steam at the atmospheric pressure. And at atmospheric density the volume of this steam is equal to 26.36 cubic feet, and this amount of steam contains 1,146 units of heat, distributed throughout the whole quantity, while the temperature at any given point at which the thermometer may be inserted is 212 degrees. If two pounds of water be evaporated, making a volume of 52.72 cubic feet, then the number of heat units present would be doubled, while the temperature would still remain at 212, the same as with one pound.

If by utilizing the heat that would otherwise go to waste, the temperature of the feed water is raised 125 degrees, the saving would be 125⁄1146 of the total amount of heat required for its evaporation, or about 11 per cent. Thus it can be seen the percentage of saving depends upon the initial temperature of the feed water, and the pressure at which it is evaporated.

For example, a boiler carrying steam at 100 pounds pressure has the temperature of the feed water raised from 60 to 200 degrees, what is the percentage of gain?

By referring to a table pressure of “saturated steam,” it will be seen that the total heat in steam at 100 pounds pressure is 1185 heat units. These calculations are from 32 degrees above zero, consequently the feed must be computed likewise.

In the first case, the heat to be supplied by the furnace is the total heat, less that which the feed water contains, or 1185 - 28 = 1157 heat units. In the second case it is 1185 - 168 = 1017 heat units, the difference being 1157 - 1017 = 140, which represents a saving of 140⁄1157 or about 12 per cent.

Where feed water is heated no more than 20 degrees above its normal temperature the gain effected cannot amount to more than 2%, not sufficient to pay for the introduction and maintenance of a feed water heating device, no matter how simple, but if the temperature of the water can be increased 60 degrees the gain will be in the neighborhood of 5%. To make feed water heating practical and economical it would be necessary to increase the temperature of the water about 180 degrees at least, and to do this, using the exhaust from a non-condensing engine without back pressure, would require such a capacity of heater as would give fully 10 square feet of heating surface to each horse power of work developed, and to raise the temperature above this would require a certain amount of back pressure or an increased capacity of heater, so that the subject resolves itself into a question of large capacity of heater, or a higher temperature of the exhaust steam, which could only be obtained through a given amount of back pressure.