Maxims and Instructions for the Boiler Room Useful to Engineers, Firemen & Mechanics; Relating to Steam Generators, Pumps, Appliances, Steam Heating, Practical Plumbing, etc.
Pipe manufactured from double thick iron is called X-strong pipe, and pipe made double the thickness of X-strong is known as XX-strong pipe. Both X-strong and XX-strong pipe are furnished plain ends—no threads, unless specially ordered.
The table “Data relating to iron pipe” will be found especially useful to the engineer and steam fitter. The size of pipes referred to in the table range from 1⁄8 to 10 inches in diameter. In the successive columns are given the figures for the following important information:
1. Inside diameter of each size.
2. Outside diameter of each size.
3. External circumference of each size.
4. Length of pipe per square foot of outside surface.
5. Internal area of each size.
6. External area of each size.
7. Length of pipe containing one cubic foot.
8. Weight per foot of length of pipes.
9. Number of threads per inch of screw.
10. Contents in gallons (U. S. measure) per foot.
11. Weight of water per foot of length.
DATA
Relating to Iron Pipe.
| Inside Diameter. | Outside Diameter. | External Circumference. | Length of Pipe per sq. ft. of Outside Surface. | Internal Area. | External Area. |
|---|---|---|---|---|---|
| Inches. | Inches. | Inches. | Feet. | Inches. | Inches. |
| 1⁄8 | .40 | 1.272 | 9.44 | .012 | .129 |
| 1⁄4 | .54 | 1.696 | 7.075 | .049 | .229 |
| 3⁄8 | .67 | 2.121 | 5.657 | .110 | .358 |
| 1⁄2 | .84 | 2.652 | 4.502 | .196 | .554 |
| 3⁄4 | 1.05 | 3.299 | 3.637 | .441 | .866 |
| 1 | 1.31 | 4.134 | 2.903 | .785 | 1.357 |
| 11⁄4 | 1.66 | 5.215 | 2.301 | 1.227 | 2.164 |
| 11⁄2 | 1.9 | 5.969 | 2.01 | 1.767 | 2.835 |
| 2 | 2.37 | 7.461 | 1.611 | 3.141 | 4.430 |
| 21⁄2 | 2.87 | 9.032 | 1.328 | 4.908 | 6.491 |
| 3 | 3.5 | 10.996 | 1.091 | 7.068 | 9.621 |
| 31⁄2 | 4. | 12.566 | .955 | 9.621 | 12.566 |
| 4 | 4.5 | 14.137 | .849 | 12.566 | 15.904 |
| 41⁄2 | 5. | 15.708 | .765 | 15.904 | 19.635 |
| 5 | 5.56 | 17.475 | .629 | 19.635 | 24.299 |
| 6 | 6.62 | 20.813 | .577 | 28.274 | 34.471 |
| 7 | 7.62 | 23.954 | .505 | 38.484 | 45.663 |
| 8 | 8.62 | 27.096 | .444 | 50.265 | 58.426 |
| 9 | 9.68 | 30.443 | .394 | 63.617 | 73.715 |
| 10 | 10.75 | 33.000 | .355 | 78.540 | 90.792 |
| Inside Diameter. | Length of Pipe containing one Cubic Foot. | Weight per ft. of Length. | No. of Threads per inch of Screw. | Contents in GallonsA per foot. | Weight of Water per foot of Length. |
| Inches. | Feet. | Lbs. | Lbs. | ||
| 1⁄8 | 2500. | .24 | 27 | .0006 | .005 |
| 1⁄4 | 1385. | .42 | 18 | .0026 | .021 |
| 3⁄8 | 751.5 | .56 | 18 | .0057 | .047 |
| 1⁄2 | 472.4 | .84 | 14 | .0102 | .085 |
| 3⁄4 | 270. | 1.12 | 14 | .0230 | .190 |
| 1 | 166.9 | 1.67 | 111⁄2 | .0408 | .349 |
| 11⁄4 | 96.25 | 2.25 | 111⁄2 | .0638 | .527 |
| 11⁄2 | 70.65 | 2.69 | 111⁄2 | .0918 | .760 |
| 2 | 42.36 | 3.66 | 111⁄2 | .1632 | 1.356 |
| 21⁄2 | 30.11 | 5.77 | 8 | .2550 | 2.116 |
| 3 | 19.49 | 7.54 | 8 | .3673 | 3.049 |
| 31⁄2 | 14.56 | 9.05 | 8 | .4998 | 4.155 |
| 4 | 11.31 | 10.72 | 8 | .6528 | 5.405 |
| 41⁄2 | 9.03 | 12.49 | 8 | .8263 | 6.851 |
| 5 | 7.20 | 14.56 | 8 | 1.020 | 8.500 |
| 6 | 4.98 | 18.76 | 8 | 1.469 | 12.312 |
| 7 | 3.72 | 23.41 | 8 | 1.999 | 16.662 |
| 8 | 2.88 | 28.34 | 8 | 2.611 | 21.750 |
| 9 | 2.26 | 34.67 | 8 | 3.300 | 27.500 |
| 10 | 1.80 | 40.64 | 8 | 4.081 | 34.000 |
A The Standard U. S. gallon of 231 cubic inches. | |||||
The division of process in the manufacture of pipe, takes place at 11⁄4 inch, 11⁄4 inch and smaller sizes being called butt-welded pipe, and 11⁄2 inch and larger sizes being known as lap-welded pipe; this rule holds good for standard, X-strong and XX-strong.
JOINTS OF PIPES AND FITTINGS.
The accompanying illustrations represent certain joints, couplings and connections used in steam and hot water heating systems.
For many years in the matter of pipe joints there has been little change. The cast-iron hub and spigot joint, Fig. 115, caulked with iron borings, is probably the oldest kind of joint. This is still generally adopted in hot water heating of a certain class, and was formerly used with low-pressure steam. A fairly regular smooth internal service is obtained, and once made tight is very durable. Cast-iron flanged pipes have also been a long time in use. These joints are made with a wrought-iron ring gasket, wrapped closely with yarn, Fig. 116, which is sometimes dipped in a mixture of red and white lead. It is placed between the flanges, it being of such a diameter as to fit within the bolts by which the joint was screwed up and a nest or iron joint, B B, caulked outside the annular gasket between the faces of the flanges.
The next step in cast-iron flange pipe joints was the facing or turning up of the flanges and the use of a gasket of rubber, copper, paper or cement, with bolts for drawing the faces together. These joints for cast-iron pipes have not been changed excepting for some classes of work where a lip and recess, Fig. 117, formed on opposite flanges, which makes the internal surfaces smooth and aid in preventing the gaskets from being blown out.
The introduction of wrought iron welded pipes has diminished the use of cast-iron pipes for many purposes, especially in heating apparatus and other pipe systems. Its advantages are lightness, the ease with which various lengths can be obtained and its strength. In wrought-iron pipe work the general practice in making joints between pipes is a wrought-iron coupling, Fig. 118, with tapered threads at both ends. The pipes do not meet at their ends, and a recess of about 3⁄4 inch or more long by the depth of the thickness of the pipes is left at every pipe end. A similar tapered thread is used in connecting the cast-iron fittings, elbows, tees, etc., Fig. 119, to the pipe, and a large recess is necessary in each fitting to allow for the tapping of the threads. Thus the inside diameter of the fitting is larger by 1⁄8 inch than the outside diameter of the pipe, and the internal projection of the thickness of the pipe and that of the thread of the fitting increases materially the friction due to the interior surfaces of pipe and fitting. This class of joint requires care in the tapping of the fittings and in the cutting of tapered threads on the pipes; much trouble is caused by an inaccurately cut thread, as it may throw a line of pipes several inches out of place and put fittings and joints under undue and irregular strains.
The right and left threaded nipple, Fig. 119, is used as a finishing connection joint and between fittings. Space equal to the length of the two threads is required between the two fittings to be connected in order to enter the nipple, and one or both fittings should be free to move in a straight line when the nipple is being screwed up. To make up this joint time and care are necessary. The right threaded end on nipple should be first firmly screwed with the tongs or wrench into the right threaded end of fitting, then slacked out and screwed up again by hand until tight, when it is screwed back by hand, at the same time counting the number of threads it has entered by hand. The same is done with the left threaded end of nipple and fitting. If the right and left threads of nipple have counted the same number of threads, each thread, when making the joint up, should enter the fittings at the same time if possible, and particular care must be taken that the fittings are exactly opposite, to facilitate catching on, prevent crossing threads, and that no irregular strain comes on the nipple while being screwed up.
In screwing up these nipples the coupling has to be turned with flats on the external surface to fit an internal wrench: in such cases the thread on nipple has one continuous taper. These special couplings are marked with ribs on the outside to distinguish them. Fig. 120 represents another joint in wrought-iron piping known as the “union” composed of three pieces of the washer. Unions are also made with ground joints, and the washer dispensed with. Radiator valves are now generally connected by them, but if the hole in the radiator is not tapped accurately, the union when drawn up will not be tight, or if tight, the valve will not be straight.
Fig. 121 shows right and left threaded nipple connecting elbow and tee with wrought-iron pipes.
The flange union, Fig. 122, is another joint generally used on wrought-iron pipes above 4 or 5 inches in diameter in making connections to valves, etc., and on smaller pipes in positions where it is a convenient joint. This joint consists of two circular cast-iron flanges with the requisite number of holes for bolts, and central hole tapped tapered to receive thread of pipe. The abutting faces of the flanges are generally turned and the holding bolts fitted into the holes.
STEAM AND HOT WATER HEATING.
The heating by means of pipes through which are conveyed hot water and steam is a science by itself and yet one claiming some degree of familiarity by all engineers, steam users, and architects.
In practice it requires a knowledge of steam, air and temperatures, of pressure and supply; a familiarity with heat and heating surfaces and with all contrivances, appliances and devices that enter into the warming and ventilation of buildings. So long as factories, public and private buildings are erected, so long will warming and ventilation keep progress with steam engineering and remain a part of the general mechanical science required of the supervisory and practical engineer.
In what is called the system of open circulation, a supply main conveys the steam to the radiating surfaces, whence a return main conducts the condensed water either into an open tank for feeding the boiler, or into a drain to run to waste, the boiler being fed from some other source; the system of what is called closed circulation is carried out either with separate supply and return mains, both of which extend to the furthest distance to which the heat has to be distributed, or else with a single main, which answers at once for both the supply and the return, either with or without a longitudinal partition inside it for separating the outward current of steam supply from the return current of condensed water.
In either case suitable traps have to be provided on the return main, for preserving the steam pressure within the supply main and radiators. These two systems, in any of their modifications, may also be combined, as is most generally done in any extensive warming apparatus.
The system of closed circulation requires the boiler to be placed so low as will allow all the return pipes to drain freely back to it above its water-level. This condition has been modified mechanically by the automatic “trap,” a device frequently employed for lifting from a lower level, part or all of the condensed water, and delivering it into the boiler; it is, in fact, a displacement pump.