The differential motion is accomplished by the device shown at the top of small cylinder.

FUEL ECONOMIZER AND FEED WATER PURIFIER.

This device, shown in Fig. 93, is designed to utilize the waste products of combustion as they pass from the furnace to the chimney. Its use permits a high and consequently efficient temperature under the boilers and yet saves the excess of heat. It acts also as a mechanical boiler cleaner, furnishing a settling chamber for the deposit of the impurities separated by the heat which nearly equals that of the live steam in the boiler. This device adds largely to the water capacity of the boiler, frequently containing one-half the weight of the water held in the boiler itself.

It will be readily understood that the openings between the vertical tubes are ample for the chimney flue area and that the device is located between the chimney and the boiler, with the waste furnace heat passing between the tubes.

Fig. 93.

The economizer shown in Fig. 93 consists of sections of vertical 41⁄2″ boiler tubes fitted to their top and bottom headers by taper joints. The top headers are provided with caps over each tube to permit cleaning out the sediment and remove and replace any tube that may become damaged. The several top headers are connected together at one end by lateral openings and the bottom headers are also connected as shown in cut, having hand holes opposite each bottom header to provide for cleaning out.

Mechanical scrapers are made to travel up and down each tube to keep them clear of soot. These are controlled by an automatic mechanism and driving head, as shown in Fig. 93.

The important features about the economizer are, 1, its adaptability to any type of boiler, 2, the saving attained by utilizing that heat which has necessarily been an almost total waste, 3, the purifying of the water by means of the intense heat and slow circulation of the feed water.

SAFETY VALVES.

Fig. 94.(Sectional View.)

The safety valve is a circular valve seated on the top of the boiler, and weighted to such an extent, that when the pressure of the steam exceeds a certain point, the valve is lifted from its seating and allows the steam to escape. Safety valves can be loaded directly with weights, or the load can be transmitted to the valve by a lever. Again, the end of the lever is sometimes held down by a spring, or the spring may be applied directly to the valve seat.

Fig. 94 (2 views) exhibits a spring loaded safety valve. These are generally provided with a reaction lip, surrounding the seat, which causes them to open much further, and thus enables them to discharge a larger volume of steam than a lever valve of equal diameter.

The operation can be easily understood by examining the figures. As soon as the steam pressure is high enough to lift the valve disc clear from its seat, the steam will escape around the valve seat as in an ordinary lever safety valve, but instead of escaping directly into the atmosphere, the current of steam is turned downward against the reaction lip, by the curved projection on the valve disc, which can be seen in the figure. The steam pressure is thus assisted in holding the valve open, as well as raising it much higher, giving a larger opening than would be the case if the valve were lifted by the pressure alone.

Spring loaded valves are mostly used on marine boilers, locomotives and portable boilers, and wherever outside disturbances interfere with the action of a weight.

A “pop” safety valve is a common form of safety valve and takes its name from the fact that it takes a little more pressure to raise it off its seat than what it is set at, consequently it releases itself with a “pop.”

Fig. 95.

Fig. 95 shows a form of dead weight safety valves when a is the valve which rests on the seating b.

The valve is attached to the circular casting A, A, A, so that both rise and fall together. The weights W, W, etc., are disposed on the casting in rings, which can be adjusted to the desired blow off pressure. Owing to the center of gravity of the casting and weight being below the valve, the latter requires no requires no guides to keep it in position. This is a great advantage as guides frequently stick, and prevent the valve from acting. Another advantage of this form of valve is, that it is difficult to tamper with. For instance, a four-inch valve, intended to blow off at 100 lbs. per square inch would require weight of over 1,200 lbs., which require a considerable bulk. An unauthorized addition of a few pounds to such a mass would make no appreciable addition to the blowing off pressure, while any effectual amount added to the weight would be immediately noticed. It is quite different with the lever safety valve about to be described, a small addition to the weight at the end of the lever is multiplied several times at the valve.

U. S. Rules Relating to Safety Valves.

Extract from rules and regulations passed and approved Feb. 25, 1885, by the United States Board of Supervising Inspectors of Steam Vessels:

Section 24. “Lever safety valves to be attached to marine boilers shall have an area of not less than one square inch to two square feet of the grate surface in the boiler, and the seats of all such safety valves shall have an angle of inclination of forty-five degrees to the centre line of their axis.

“The valves shall be so arranged that each boiler shall have one separate safety valve, unless the arrangement is such as to preclude the possibility of shutting off the communication of any boiler with the safety valve or valves employed. This arrangement shall also apply to lock-up safety valves when they are employed.

“Any spring-loaded safety valves constructed so as to give an increased lift by the operation of steam, after being raised from their seats, or any spring-loaded safety valve constructed in any other manner, or so as to give an effective area equal to that of the aforementioned spring-loaded safety valve, may be used in lieu of the common lever-weighted valve on all boilers on steam vessels, and all such spring-loaded safety valves shall be required to have an area of not less than one square inch to three square feet of grate surface of the boiler, and each spring-loaded valve shall be supplied with a lever that will raise the valve from its seat a distance of not less than that equal to one-eighth the diameter of the valve opening, and the seats of all such safety valves shall have an angle of inclination to the centre-line of their axis of forty-five degrees. But in no case shall any spring-loaded safety valve be used in lieu of the lever-weighted safety valve, without first having been approved by the Board of Supervising Inspectors.”

The following size “Pop” Safety Valves are required for boilers having grate surfaces as below:

2    inch “Pop” Valve for9.42square feet of grate surface.
21⁄2 inch “Pop” Valve for14.72square feet of grate surface.
3    inch “Pop” Valve for21.20square feet of grate surface.
4    inch “Pop” Valve for37.69square feet of grate surface.
5    inch “Pop” Valve for58.90square feet of grate surface.
6    inch “Pop” Valve for84.82square feet of grate surface.

Professor Rankin’s Rule.—Multiply the number of pounds of water evaporated per hour by .006, and the product will be the area in square inches of the valve.

The U. S. Steamboat Inspection Law requires for the common lever valve one square inch of area of valve for every two square feet of area of grate surface.

United States Navy Department deduced from a series of experiments the following rule: Multiply the number of pounds of water evaporated per hour by .005, and the product will be the area of the valve in square inches.

Rule adopted by the Philadelphia Department of Steam Engine and Boiler Inspection:

1. Multiply the area of grate in square feet by the number 22.5. 2. Add the number 8.62 to the pressure allowed per square inch. Divide (1) by (2) and the quotient will be the area of the valve in square inches. This is the same as the French rule.

The maximum desirable diameter for safety valves is four inches, for beyond this the area and cost increase much more rapidly than the effective discharging around the circumference.

There should not be any stop valve between the boiler and safety valve.

The common form of safety valve is shown in Fig. 96.

Here the load is attached to the end B of the lever A, B, the fulcrum of which is at c. The effective pressure on the valve, and consequently the blowing off pressure in the boiler can be regulated within certain limits, by sliding the weight W along the arm of the lever. In locomotive engines, as well as on marine boilers, the weight would on account of the oscillations, be inadmissible and a spring is used to hold down the lever.

In the calculations regarding the lever safety valve, there are five points to be determined, and it is necessary to know four of these in order to find the fifth. These are: (1) The Steam Pressure, (2) The Weight of Ball, (3) The Area of Valve, (4) The Length of Lever, (5) The Distance from the Valve Centre to the Fulcrum.

Fig. 96.

In making these calculations it is necessary to take into account the load on the valve due to the weight of the valve-stem and lever. The leverage with which this weight acts is measured by the distance of its centre of gravity from the fulcrum. The centre of gravity is found by balancing the lever on a knife edge, and the weight of the valve-stem and lever can be found by actual weighing. This load can also be found by attaching a spring balance to the lever exactly over the centre of the valve stem when they are in position. The following examples will be computed under these conditions: (1) Steam Pressure, 120 pounds; (2) Weight of Ball, 100 pounds; (3) Weight of Valve and Lever, 60 pounds, weighed in position; (4) Length of Lever, 45 inches; (5) Length of Distance from Valve Centre to Fulcrum, 5 inches; (6) Area of Valve, 8 square inches.

To find the area of the valve:

Rule.—Multiply the length of the lever by the weight of the ball, and divide the product by the distance from the valve centre to the fulcrum, and to the quotient add the effective weight of the valve and lever, and divide the sum by the steam pressure.

Example.

 45     inches, length of the lever,
 100pounds, weight of the ball,
Fulcrum, 5 in. )4500 
 900 
 60pounds, weight of valve and lever,
Steam pressure 120 lbs. )960(8 square inches, area of valve.
 960 

To find the pressure at which the valve will blow off:

Rule.—Multiply the length of the lever by the weight of the ball; divide this product by the distance from the valve centre to the fulcrum, and to the quotient add the effective weight of the lever and valve, and divide the sum by the area of the valve.

Example.

 45     inches, length of lever,
 100pounds, weight of ball,
Fulcrum, 5 in. )4500 
 900 
 60pounds, weight of valve and lever,
Area of Valve 8 )960 
 120pounds, pressure at which valve will blow.