River and Canal Engineering, the characteristics of open flowing streams, and the principles and methods to be followed in dealing with them.
In all cases the loss is supposed to be 14 inches annually. If it is 15 or 13 inches, the reservoir capacity is less or more by about five, ten, or fifteen million gallons, according as the number of years in column 1 is 1, 3, or 6. And the daily yield is less or more by about 50,000 gallons.
With a low rainfall the advantage of a large reservoir is somewhat increased. The capacity of the six-year reservoir for a fall of 30 inches is 63 per cent. more than that of the three-year reservoir, but the supply is 22 per cent. greater.
The figures given above for reservoir capacities are suitable for the British Isles. They assume that the distribution of the rainfall is the least favourable that is at all likely to occur. Deacon states that the figures do not relieve the engineer of the exercise of judgment. As regards the British Isles, the chief questions on which judgment has to be exercised are whether to equalise the flow of three years or of another number, and how much to allow for loss. As already stated, three years is the period usually taken. The figures are suitable for most places in Europe, but in some places, e.g. on the Mediterranean coast, the distribution of the rainfall is somewhat less favourable than in the British Isles. In other parts of the world, and notably in or near the tropics, the distribution of the rainfall must be specially studied, and a diagram be prepared on the same principle as in the case of fig. 58. The diagram should be extended to cover the desired number of years. In hot countries loss by evaporation from the surface of the reservoir should be allowed for. In India during the hot dry months this loss may be half an inch in twenty-four hours.
In the article above quoted it is shown that if, as commonly happens, the consumption of water is, in summer, greater than the mean, and in winter less, the conditions are still more trying for the reservoir; and that in the case where the summer consumption is 13 per cent. greater than the mean, the capacity of the reservoir which impounds the water of the driest year must be 33 per cent., instead of 30 per cent., of the total supply impounded during the year. It would then contain 121 days’ instead of 110 days’ mean supply. In the table on page 170 the number of days’ supply is 113. From this it appears that the tables from which extracts have been given are calculated on the basis of a constant consumption. This, however, in the case where the number of years whose supply is equalised is greater than one, makes, owing to the increased size of the reservoir, no practical difference.
The calculations for the great reservoirs in Radnorshire for the supply of the city of Birmingham are as follows (Min. Proc. Inst. C.E., vol. clxxx.). The ratio of the mean fall in the three driest years to the mean annual fall was taken as ·80 instead of ·77. There is some difference of opinion as to the best figure:—
| Mean annual fall determined from readings of various gauges | 65 | inches |
| Mean fall of three driest years | 52 | ” |
| Deduct loss from evaporation and absorption and losses during floods | 15 | ” |
| Available rainfall | 37 | ” |
This multiplied by 44,000 acres, the area of the catchment, gives 102 million gallons per day. Of this, 27,000,000 gallons is compensation water, leaving 75,000,000 gallons for Birmingham. Capacity of reservoirs, 17,250,000,000 gallons, or 169 days’ supply.
3. Earthen Dams.—Before an earthen dam is made, any soft soil on the site should be removed and the ground downstream of the site should be drained. A few trenches, running parallel to the axis of the dam, can be dug so as to give the dam a hold, though there is never any danger of its being moved horizontally by the thrust of the water. If the ground has a side-long slope it should be benched as shown in fig. 59. The front slope of an earthen dam is generally about 3 to 1, and the rear slope about 2 to 1. The top has a width of ⅓ to ½ the greatest depth of water held up, and is 5 to 10 feet above the highest water-level. The borrow pits from which the earth for the dam is got should not be near enough to it to in any way affect its stability.
In England, and generally in other countries, an earthen dam has a core-wall (fig. 60) which is carried down to an impervious stratum, and is keyed into it to a depth of a foot or more in the case of hard rock and several feet in the case of clay. On this core-wall the impermeability of the dam chiefly depends. The core-wall may be of clay puddle, concrete, or masonry. In England it is generally of clay puddle. The core-wall sometimes extends down to a depth of 100 or 200 feet. Its top is horizontal and about level with the highest water-level. It is desirable not to make the foundation stepped, but to let it follow the profile of the impervious stratum. The wall is keyed at its ends into the sides of the valley or gorge. A core-wall of concrete or masonry is, in a high dam, necessarily a comparatively thin structure, and it may be subjected to great strains by unequal pressures of the earth which surrounds it. It is therefore to some extent liable to crack. A core-wall of concrete used for the water-works of Boston, U.S.A., is 100 feet high, 8 feet thick at the base, and 4 feet thick at the top. A clay-puddle wall, being plastic and moist, at least during the period immediately succeeding the construction of the work, is not very liable to crack. The top width of a puddle wall may be 4 to 10 feet, and the batter of the sides from 1 in 20 to 1 in 8. The clay used for the wall above the ground-level should contain about 33 per cent. of sand and stones. This diminishes its shrinkage if it dries. It should not be given too much water in mixing. It should be thoroughly mixed and worked up and trodden down.
The clay puddle and the earth of the dam should be carried up uniformly. The allowance for settlement may be 1/30 to 1/50. The earth should be deposited in thin layers, moistened and rammed, and all clods broken. In India and some other countries, instead of the earth being rammed, cattle or sheep are driven over it repeatedly. This makes earthwork of most excellent quality, and the settlement, if any, is very small.
In cases where, owing to a fissure in the rock below the bottom of the puddle trench, water comes through under the puddle, it is usual to carry it away in a pipe running vertically in a groove up the side of the trench and then horizontally till it emerges from the dam. Such water, and any other leakage, can often in Great Britain be used as part of the compensation water. There is, however, a certain chance, when there are water-bearing fissures in the rock below the bottom of the trench, that some percolating stream of water may wash away the puddle, and it is preferable to use a concrete core-wall in such cases, carrying it up to about ground-level and keying it into a much thicker wall of puddle which is carried up to the water-level.
It has been suggested that the clay puddle or other impervious layer should be placed, not vertically and in the middle of the dam, but lying on the upstream face of the dam, so as to keep out water from the whole dam instead of from only half of it. Objections to this, if clay puddle is used, are that vermin may bore holes in it, and that, with some clays, it would slip. These objections might be overcome to some extent by laying a pitching of concrete blocks over the puddle. Other objections, applying also when masonry or concrete is used, are that the superficial area and cost are increased, and that cracks would occur from settlement of the earth and from changes of temperature when the water in the reservoir was low. A good many cases have occurred in which an impervious layer laid on the slopes has failed from one cause or another. In France it is usual to rely on such a layer—concrete is used—and to dispense with a core-wall. The practice of having a vertical wall appears to be the best, and is the most widely adopted. When puddle is used the weight of the mass above it forces it to completely fill the trench, and when once it is in position and covered up it is not at all likely to be damaged.
The outer portion of a high embankment sometimes slips (fig. 61), and precautions should be taken against this. A slip may occur if the site of the dam has not been carefully selected as to geological formation, or if there is unequal settlement owing to the work having been done at different times. One cause of slips is sudden and partial changes in the degree of saturation, and another cause is excessive saturation. Some clays when wet require extremely flat side slopes, and will not stand even at 5 to 1. The outer parts of the embankment are not required for stopping percolation (this will be further considered in the following paragraph), and, though they must be carefully laid and consolidated, they should be of porous material, and the part on the downstream side of the dam must be well drained. A series of surface drains may be arranged and filled with loose stone and gravel. There is also a distinct advantage in using heavy material such as small stone for the lowest portion of the outer parts on both sides of the dam. When good material cannot be obtained, the side slope on the downstream side of the dam may be flattened. A side slope starting at the top with 3 to 1 and becoming 4 to 1 lower down, and finally 5 to 1 at the base, is a very good form for prevention of slipping and generally for the safety of a dam. The part on the side next the reservoir is not likely to slip. It becomes soaked, but it has the pressure of the water against it and is pitched. In Madras, where reservoirs are very numerous, the slope on the side next the water is generally only 1½ to 1.
The different parts of an earthen dam fulfil two distinct functions. Some parts, which may be called the staunches, have to stop the percolation of water from the reservoirs. Other parts, which may be called the supports, have merely to hold up the staunches. In the British type of dam the portion nearest the core-wall on either side (fig. 60) is generally made of earth specially selected for impermeability. The distance to which it extends from the wall depends partly on the quantity of such earth available. In any case it has to be very carefully made and consolidated, to avoid unequal pressures on the core-wall, or unequal settlement which might cause it to part from the wall. One of its functions is to keep the core-wall moist when the water-level in the reservoir falls. Whether it is also to be considered as a staunch or a support might at first appear to be of no consequence, but it is of importance as affecting the question of drainage. The support on the downstream side of the dam must, as has just been seen, be made of porous material and be well drained; but obviously a staunch must not be porous, nor can it be penetrated by drains. The question must be decided in each case according to judgment. In a discussion which took place on the above-mentioned paper by Strange, at the Institution of Civil Engineers, much diversity of opinion was expressed among eminent engineers as to the desirability of draining the downstream half of the dam, i.e. the part downstream of the core-wall. By some it was urged that drainage is necessary to lessen the chance of the earthwork slipping. Others contended that any drain which penetrates the dam must facilitate the percolation of water from the reservoir. It is clear that some of the speakers regarded the dam downstream of the core-wall as being partly staunch, and some as being wholly support. If for any reason there seems a chance of water leaking through the core-wall, it is desirable to regard the earth-filling next to it as staunch.