Pandipedia entry
Updated 22 Nov 20263 sourcesBrowse Pandipedia
Research report

Why an atomic fountain sends atoms through the microwave twice

NIST’s cesium fountain uses the atoms’ flight to make a more precise frequency measurement. The same cloud encounters microwaves on the way up and on the way down. The pause between the two encounters helps the clock distinguish very small frequency differences. [1] [2]

One cloud, two encounters

A cesium fountain is named for the path of the atoms. Lasers first slow a cloud of cesium atoms. A vertical push of laser light sends it up a vacuum tube, and gravity brings it back down. The cloud passes through the same microwave cavity twice. [3]

StageWhat it does
Cool and loftSlow the cloud down and send it up the tube. [4]
Pass up and downExpose the same atoms to microwaves twice with free flight in between. [5] [6]
Read and adjustCount how many atoms end up in the higher energy state. [7] [8]

The light signal is a readout of the atoms’ state after the two microwave encounters. [9]

Why the pause sharpens the comparison

The first pulse prepares the atoms in a combination of two energy states. During free flight, that combination evolves at a natural frequency called the cesium resonance. The second pulse turns any mismatch between the microwave and atomic frequencies into a difference the detector can measure. When the frequency is close to resonance, more atoms finish in the higher state. [10] [11]

The longer the gap between pulses, the more a small mismatch can build up. NIST contrasts nearly a second between pulses in a fountain with only milliseconds in a beam clock. Keeping the cloud in free flight between the two measurements makes it easier to tell two nearby microwave frequencies apart. [12]

From a resonance to a second

An oscillator is the electronics that supply a repeating signal. Atoms in the fountain provide the frequency reference. NIST’s readout counts how many atoms changed state on each trial, and the clock adjusts its microwave signal toward the frequency that gives the strongest response. Timekeeping labs can use that checked frequency to calibrate other clocks. [13] [14]

The SI second is defined by fixing the frequency of a particular transition in cesium-133 at 9,192,631,770 cycles per second. The fountain is one way to measure a signal against that reference. Researchers are developing optical clocks that may support a future definition. [15] [16]

Continue exploring
Browse all