How much water does one AI chatbot query use? Every published figure, and what each one counts
Somewhere between almost nothing and about 50 millilitres, about three tablespoons at most, depending on who counts and what they count. Yes, AI chatbots use water, mainly to cool data centres and to make the electricity they run on. Google, OpenAI's chief executive and Microsoft all put a text query under a third of a millilitre: Google says 0.26 mL[1], Sam Altman says about 0.32 mL[2], and Microsoft says 0 to 0.067 mL[3]. Mistral's life-cycle figure and a university study, which also count power-plant water or hardware, run from about 17 to 50 mL[4][5]. The famous "bottle of water" is a 500 mL bottle spread over 10 to 50 responses from GPT-3, not one query[6].
Last updated 25 November 2026. Figures are as each source published them, converted to millilitres per query.
| Who | mL per query | Counts |
|---|---|---|
| Microsoft, 2026[7] | ▏ 0–0.067 | Cooling water, estimate |
| Google, 2025[8] | ▏ 0.26 | On-site cooling only |
| Sam Altman (OpenAI), 2025[9] | ▏ 0.32 | Not stated |
| UC Riverside study, US average[10] | ▇▇▇ 16.9 | Cooling plus power-plant water |
| Mistral, 2025[11] | ▇▇▇▇▇▇▇▇▇ 45 | Life cycle, incl. hardware |
| UC Riverside study, top of range[12] | ▇▇▇▇▇▇▇▇▇▇ 50 | Cooling plus power-plant water |
What we know
- The low figures count only cooling. Google's 0.26 mL is water evaporated on site, worked out from the prompt's energy and Google's fleet-wide water efficiency[13]. Microsoft's range is also cooling water[14].
- Power plants are usually the bigger share. In the UC Riverside study's US average, cooling is 2.2 mL of 16.9 mL, or 13%; the rest is water used to make the electricity[15]. Meta's report shows the same at company scale: 26,101 million gallons embedded in purchased electricity in 2025, against 790 million gallons used directly, about 33 times more[16].
- One company figure comes with no method at all. Altman's figure arrived in one sentence of a blog post with no boundary or method stated[17][18].
- Anthropic and Meta have published no per-query figure. We checked Anthropic's data-centre commitments page[19] and Meta's 2026 sustainability report[20].
The ledger
One row per published per-query figure, plus the companies we checked that have none.
| Who and when | Figure | What it counts and method |
|---|---|---|
| Li, Yang, Islam, Ren (UC Riverside, UT Arlington). 2023, revised March 2025[21] | "A 500ml bottle" per 10–50 responses = 10–50 mL. Its own table: 7.1 mL (Ireland) to 47.5 mL (Washington); US average 16.9[22] | GPT-3 in Microsoft data centres. Cooling water plus water used at power plants. A request of up to 800 words in and 150–300 words out, assumed to take 0.004 kWh. Training and hardware left out[23] Method published: Yes: formula and every input |
| Mistral AI, 22 July 2025[24] | 45 mL per 400-token Le Chat response[25] | Mistral Large 2. A life-cycle figure that includes making the servers, not users' devices. Training is reported separately: 281,000 m³[26] Method published: Partly: summary and standards named; full study not posted[27] |
| Sam Altman, OpenAI chief executive, June 2025[28] | "0.000085 gallons" per average ChatGPT query = 0.32 mL | Not stated[29] Method published: No. Google's paper notes it gives no boundary or method[30] |
| Google, August 2025[31] | 0.26 mL for the median Gemini Apps text prompt, May 2025; 0.15 mL on a narrower count[32] | On-site cooling water only, at a fleet average of 1.15 litres per kWh. No power-plant water, no training[33] Method published: Yes: formula and inputs[34] |
| Microsoft, 15 June 2026[35] | 0.0–0.067 mL for "a typical query"[36] | Cooling water, for large production models "under conservative assumptions"[37] Method published: In a Joule paper we could not open; the preprint gives energy only[38] |
| EcoLogits (open-source calculator)[39] | No single figure; varies by model and provider | Cooling plus power-plant water, using the UC Riverside formula. No water for making hardware[40] Method published: Yes: open methodology[41] |
| Anthropic[42] | No published figure | Says its own data centres "require little to no water" and promises yearly site metrics[43] |
| Meta[44] | No published figure | Publishes yearly company totals only[45] |
Why the numbers differ
- What is counted. On-site cooling only (Google, Microsoft), cooling plus power plants (UC Riverside, EcoLogits), or a full life cycle including making the servers (Mistral)[46][47][48][49][50]. This alone can move a figure several-fold.
- Energy per query. Water is worked out from energy. UC Riverside assumed 0.004 kWh for a GPT-3 request in 2023[51], about 16.7 times Google's measured 0.24 Wh for a median Gemini prompt in 2025[52]. Microsoft puts a typical query at 0.16–0.60 Wh[53].
- Where the data centre is. In the UC Riverside table, the same request ranges from 7.1 mL in Ireland to 47.5 mL in Washington, because cooling and local power plants differ[54].
- Model size and answer length. Mistral says impacts are roughly proportional to model size[55]. Its figure is for a 400-token answer; Google's is for the median prompt, which may be shorter[56][57].
- Average, median or typical. Altman gives an average[58], Google a median[59], Microsoft a "typical" query[60]. None covers long reasoning tasks, images or video.
Shaolei Ren, an author of the UC Riverside study, put it this way in October 2025: "Each number is correct within its own context, but direct comparisons are not meaningful"[61].
What is still unknown
- What Altman's figure counts, and whether it includes power-plant water[62].
- Any figure for Claude or Meta AI[63][64]. Anthropic says its own data centres are air-cooled and closed-loop, but that is a design claim, not a per-query number[65].
- Microsoft's method. We could not open the Joule paper behind its range; the preprint has no water figure[66].
- Unverified, not in the ledger: a Washington Post estimate of a bottle per 100-word email (the page blocked us), and reports that Ren now puts a GPT-4 prompt near 15 mL. We found no Ren publication saying so.
What would settle it
Every company publishing water per query with the same boundary: on-site cooling plus power-plant water, for named models and query lengths, checked by a third party. Mistral and Ren both call for a common standard[67][68].
How this page was made
We opened each source on 25 November 2026 and saved a copy. A script converts each figure to millilitres per query (1 US gallon = 3,785.41 mL), checks each quoted number against the saved text, re-adds the UC Riverside table and recomputes Google's figure from its own formula. Company figures are what each company says; we have not checked them. This page was drafted with Claude, an AI model made by Anthropic. Anthropic is an AI company with its own data-centre water footprint and is one of the companies in the ledger.
Let's look at alternatives:
- Modify the query.
- Start a new thread.
- Remove sources (if manually added).