Now, to allow for sudden or extra strains, call 8000 lbs. the strain to be supported by each brace, and, accordingly, 8 square inches of sectional area would be sufficient for compression only; but, as the brace is inclined, the strain is increased. Let the vertical distance from A to D be 10 ft., and, calling the span 30 ft.—A B will be 15 ft.—from whence D F must be 18 ft., then we shall have the proportion

10:18::8000:14400 lbs.

which would require an area of about 15 square inches of section to resist compression, or a piece 3x5 inches. Now, as this stick is more than 6 or 8 diameters in length, it will yield by bending—and consequently its area must be increased. The load, which a piece of wood acting as a post or strut will safely sustain, is found by the formula already given.

Equation: W = 2240 bd^3 / L^2

Now substituting 3 for b, and 5 for d, we have

Equation: W = 2240 x 3 x 125 / 324 = 840000 / 324
= 2592 lbs.

which is not enough. Using 6 for b and 8 for d, we have

Equation: W = 2240 x 6 x 512 / 324
= 21238 lbs.

which is something larger than is actually required, but it is no harm to have an excess of strength. Now in many cases this arrangement would be objectionable, as not affording sufficient head room on account of the braces—and we can as well use the form of structure given in Pl. I. Fig. 3, since it is evidently immaterial whether the point B be supported on F or suspended from it, provided we can prevent motion in the feet of the braces, which is done by notching them into the stringer at that point. This of course creates a tensional strain along the stringer, which is found as follows:—Representing the applied weight by FB, Pl. II, Fig. 2, draw BD parallel to FC, also DH parallel to AC—DH is the tension. This is the graphical construction, and is near enough for practice. Geometrically we have the two similar triangles AFB and DFH, whence

AF: DF:: AB: DH

and
Equation: DH = DF x AB / AF

This style of structure may be used up to 50 feet, but it is not employed for spans exceeding 30 feet in length. It is very customary to make the braces in pairs so as to use smaller scantling, and gain in lateral stiffness—the two pieces forming one brace by being properly blocked and bolted together. Below is given a table of dimensions for the various parts of this style of structure:

Span.Rise.Bolster.Stringer.Braces.Rod.
    No.Size. 
15612 x 1212 x 1225 x 61⅛
20714 x 1412 x 1325 x 81⅜
25814 x 1412 x 1526 x 81½
301014 x 1412 x 1826 x 91⅝

Single Beams under each rail firmly braced laterally, and trussed by an iron rod, (or preferably by two iron rods,) and a post on the under side of the beam. The deflection of the rod is usually taken at 1/8 of the span. Pl. II., Fig. 1, represents this style of trussing a beam—which is generally used for spans of from 15 to 30 ft. Below is a table of dimensions for this truss with single and double rods; if double rods are used only half the given section will be necessary for each one of the pair.

Span.
Feet.
Rise.
In Feet.
Stringer.
 
Post.
 
Rod.
(single.)
Rods.
(double.)
151⅞12 x 126 x 82⅛ diam.or 1½ diam.
202½12 x 147 x 82½  "1¾  "
253⅛12 x 168 x 82¾  "2    "
303¾13 x 189 x 93    "2⅛  "

It is as well to tenon the post into the beam, and also strap it firmly with iron plates—and the end should be shod with iron to form a saddle for the rods to bear upon.

Now if we should make a bridge, on the plan of Fig. 3, Pl. I., 75 or 100 feet, or perhaps more, in length, the braces AF and FC, would not only be very long but very large and heavy, and one chief requisite in a good bridge is, to have all the beams so proportioned that they will resist all the strains acting upon them, without being unnecessarily large. It now becomes necessary to have a different arrangement of the parts of the truss in order to obtain increased length of span.

Suppose we have a span, of 40 feet, as represented in Fig 2, Pl. I. Now instead of running the braces from AC until they meet in a point, as before we stop them at a, and c, and place the straining beam, ac, between them to prevent those points from approaching, suspend the points B and D from them, and start the braces Bb and Db—and, if the truss were longer, would continue on in the same manner as far as needful.

To prevent the truss from altering its form, as shown by the dotted lines A'bC', and AEC, by any passing load, we insert the counter braces marked R.

The braces Aa and Cc, must support all of tho weight of the bridge and its load within the parallelogram BacD—and the next set of braces, Bb and Db, sustain that part of the load which comes over the centre of the bridge. Consequently the braces must increase in size from the centre towards the abutments. The rods resist the same pressure in amount as their braces—but being vertical, do not need the increase, given to the braces on account of their inclination—but increase simply with the strain upon them, from the centre to the ends of the truss.

There are many forms of small bridges differing from those enumerated, in various minor details, but sufficient has been said to give the reader a fair idea of the strains upon the different parts, and how to arrange and proportion the materials to resist them.

PRACTICAL RULES AND EXAMPLES IN WOODEN BRIDGE BUILDING.

In any case that may arise, we must determine approximately the gross weight of the bridge and its load—as a basis, and then we can proceed as follows—in case of a Howe, Pratt, or Arch Brace Truss.

To find the dimensions of the Lower Chord.

The tension at the centre of the Lower Chord is found by dividing the product of the weight of the whole bridge and load by the span, by eight times the height—or letting T=tension in lbs., W=weight of bridge and load in lbs., S=span in feet, and h=rise or height—we have
Equation: T = W x S / 8h
—. In this case we have taken the rise at ⅛ of the span, which is evidently the best ratio between those dimensions, as it equalizes the vertical and horizontal forces. As to the proportions of the bays or panels, (or that portion of the truss bounded by two adjacent verticals, as struts or ties, and the chords,) the ratio of the rise (or the vertical distance between the centre lines of the two chords,) and the length on the chord should be such, that the diagonal truss members may make an angle of about 50° with the chords; as the size of the timbers is increased by decreasing the angle, and, if the angle is increased, there are more timbers required.

Mr. G.L. Vose, in his admirable work on R.R. Construction, observes very truly that "The braces, at the end of a long span, may be nearer the vertical than those near the centre, as they have more work to do. If the end panel be made twice as high as long, and the centre panel square, the intermediates varying as their distance from the end, a good architectural effect is produced."

Now it is necessary for us to have some data from which to determine the approximate weight of the bridge, and also its load. These can be found by comparing weights of bridges in common use, as obtained from reports. In a small bridge of short span, the weight of the structure itself may be entirely neglected, because of the very small proportion the strains caused by it bear to those due to the load;—but, in long spans, the weight becomes a very important element in the calculations for strength and safety—inasmuch as it may exceed the weight of the load.

In all Bridges of 120 ft. span, about ⅓ of a ton, per foot run, will be the weight of each truss for a single track, including floor timbers—transverse bracing, &c. If the bridge were loaded with Locomotives only, the greatest load would be, on the whole bridge—160 tons = 1.33 tons per ft. run of the bridge or .666 tons per ft. run of each truss. Now if we make the rise of the bridge 15 ft., and divide the span into 12 panels of 10 ft. each, we shall have for total weight of bridge and load 240 tons, or for a single truss 10 tons to each panel.

Lower Chords. Now to find the tension on the Lower Chords,
Equation: T = W x S / 8h
and supplying values, we have
Equation: T = 240 x 120 / 8 x 15
= 240 tons, or 537600 lbs., for the two Lower Chords, and ½ of this, or 268800 lbs. for one chord. The Tensional Strength of timber for safety may be taken at 2000 lbs. per square inch of section, and hence the area of timber required to sustain the above strain will be 268800 ÷ 2000 = 134.4 sq. inches. But this chord has also to sustain the transverse strains arising from the weights passing over it, and, as in the case of a Locomotive, the weight of 20 tons on 2 pair of drivers, (or 10 tons for one truss,) may be concentrated on the middle point of a panel—the chord must be so proportioned as to safely bear, as a horizontal beam, this weight. Suppose we take three sticks of 8" x 12", to form the chord (the greater dimension being the depth,) we shall have 3 x 8" x 12" = 288 square inches area of section, and
allowingfor splicing72squareinches,
""foot blocks,24""
""bolts,24""
""washers,8""

we shall have after deducting allowances (288-128) 160 square inches area, giving an excess over 134.4, the area demanded, sufficient to cover allowances for any accidental strain.

Upper Chords. The upper chords are compressed as forcibly as the lower ones suffer tension—owing to the action and reaction of the diagonals. In this case the compression is 268800 lbs., and as 1 square inch of section will safely bear 1000 lbs., we have for the area required, 268800 ÷ 1000 = 268.8 square inches,—three pieces 8" x 11" will give 264 square inches and this area will require no reduction, as the whole chord presses together when properly framed and is not weakened by splicing. So far, the calculations made would apply to either of the three Bridges mentioned, as well as to a Warren Truss. But now, to obtain the dimensions of the web members, so called, of the Truss, it is necessary to decide upon the specific variety. The form of Bridge in more general use in the United States is called the Howe Truss, from its inventor, and in spans of 150 feet, and under, is very reliable; for spans exceeding 150 ft. it should be strengthened either by Arch Braces or by the addition of Arches, as the heavy strains from the weight of bridge and load bearing on the feet of the braces near the abutments, tend to cripple and distort the truss by sagging, although the Baltimore Bridge Co. have built a Wooden Howe Bridge of two Trusses of 300 ft. span, 30 ft. rise, and 26 ft. wide, without any arch, but it has a wrought iron lower chord, and is only proportioned for a moving load of 1000 lbs. per ft. run.

VideVoseonR.R.construction.Vide Vose on R.R. construction.