All public Sources
Public document

A Treatise on Meteorological Instruments Explanatory of Their Scientific Principles, Method of Construction, and Practical Utility

DocumentAdded to Pandi 6 November 2026
Reading progressPage 33 of 35

In the above Table, columns 1 to 10 are results obtained at the Royal Observatory, Greenwich, by J. Glaisher, Esq., F.R.S. The data contained in columns 2 and 10, are deduced from observations extending over the years 1841 to 1855 inclusive, and are copied from Edward Hughes’ Third Reading Book; the other columns are results of observations made during the twenty years ending 1861. The rest of the information is from Luke Howard’s Climate of London.

These valuable data indicate the characteristics of the weather in each month in the suburbs of London, and will be found tolerably accurate as indications of weather, and serviceable as standards for comparisons of observed results, at most places in England.


STANDARD WORKS ON METEOROLOGY

SUPPLIED BY NEGRETTI & ZAMBRA.

THE WEATHER BOOK:
A MANUAL OF PRACTICAL METEOROLOGY.
By Vice-Admiral FitzRoy, F.R.S., M.I.F., &c.
Price, £0 15 6

THE LAW OF STORMS,
By H. W. Dove, F.R.S.
Translated by R. H. Scott, M.A.
Price, £0 10 6

L. F. KÆMTZ’S “COMPLETE COURSE OF METEOROLOGY,”
Translated by C. V. Walker, Esq.
Price, £0 12 6

PRACTICAL METEOROLOGY,
By John Drew, Ph.D., F.R.A.S.
Price, £0 5 0

HYGROMETRICAL TABLES,
Adapted to the use of the Wet and Dry Bulb Thermometer,
By James Glaisher, Esq., F.R.S.
Price, £0 2 6

TABLES OF THE CORRECTIONS FOR TEMPERATURES,
To reduce observations to the 32° Fahrenheit, for Barometers with brass scales
extending from the cistern to the top of the mercurial column,
By James Glaisher, Esq., F.R.S.
Price, £0 1 0

TABLE OF THE DIURNAL RANGE OF THE BAROMETER,
By James Glaisher, Esq., F.R.S.
Price, £0 0 6

TABLES FOR CALCULATION OF HEIGHTS FROM OBSERVATIONS
ON THE BOILING-POINT OF WATER,
Adapted to the use of Negretti and Zambra’s Boiling-point Apparatus.
Price, £0 1 0

A THERMOMETRICAL TABLE,
ON THE SCALES OF FAHRENHEIT, REAUMUR, AND CENTIGRADE,
By Alfred S. Taylor, Esq., M.D., &c.
Price, in Sheet, with explanatory Pamphlet, £0 1 6

METEOROLOGICAL TABLES,
For the reduction of Barometrical and Hygrometrical Observations, Determination
of Heights by the Barometer and Boiling-point Thermometer, &c.
By G. Harvey Simmonds, M.B.M.S.
Price, £0 2 6

BAROMETER MANUAL,
Compiled by Vice-Admiral FitzRoy, F.R.S.,
For the Board of Trade.
Price, £0 0 6

POCKET METEOROLOGICAL REGISTER AND NOTE-BOOK,
With Diagrams for exhibiting the Fluctuations of Barometer, &c.
Printed on metallic paper. Price, with Pencil, £0 3 0

LONDON:
PRINTED BY STRAHAN AND WILLIAMS,
7 LAWRENCE LAND, CHEAPSIDE, E.C.


NEGRETTI & ZAMBRA’S
PATENT RECORDING AND DEEP-SEA THERMOMETER. [20]

This Thermometer differs from all other Registering or Recording Thermometers in the following important particulars:—

I. The Thermometer contains only Mercury without any admixture of Alcohol or other fluid.

II. It has no indices or springs, and its indications are by the column of Mercury only.

III. It can be carried in any position, and cannot possibly be put out of order except by actual breakage of the instrument.

And lastly, it will indicate and record the exact temperature at any hour of the day or night, or the exact temperature at any depth of the sea, irrespective of either warm or cold currents, or stratum through which the Thermometer may have to pass in its descent or ascent, this last very special quality renders this Thermometer superior for deep-sea temperatures to any others; for those now being used in the “Challenger” sounding expedition are liable to give erroneous indications owing to their indices slipping, and otherwise getting deranged—(This was proved by Messrs. Negretti and Zambra at a Meeting of the British Meteorological Society,) and under certain conditions of temperature it is not possible by the old Thermometers to obtain true temperatures at certain depths which might be required. Annexed is a copy of a report to the Admiralty from Captain G. S. Nares, of H.M.S. “Challenger,” dated Melbourne, March 25th, 1874, which we have taken from Nature, July 30th, 1874, proving the assertion.

“In the report to the Admiralty of Capt. G. S. Nares, of H.M.S. Challenger dated Melbourne, March 25, 1874, Capt. Nares, speaking of the temperature of the ocean, especially near the pack edge of the ice, says:—‘At a short distance from the pack, the surface water rose to 32°, but at a depth of 40 fathoms we always found the temperature to be 29°; this continued to 300 fathoms, the depth in which most of the icebergs float, after which there is a stratum of slightly warmer water of 33° or 34°. As the thermometers had to pass through these two belts of water before reaching the bottom, the indices registered those temperatures, and it was impossible to obtain the exact temperature of the bottom whilst near the ice, but the observations made in lower latitudes show that it is about 31°. More exact results could not have been obtained even had Mr. Siemens’s apparatus been on board.’ It seems to us that the difficulty mentioned is one which would certainly have been surmounted by Messrs. Negretti and Zambra’s new Recording Thermometers, a description of which appeared in Nature, vol. ix. p. 387; this being exactly one of the cases to which this instrument is peculiarly adapted. We believe the inventors and makers have greatly improved their Thermometer since our description appeared, and no doubt means will be taken by the Admiralty to transmit one to the Challenger.”


Fig. 1.

DESCRIPTION OF THE DEEP-SEA RECORDING THERMOMETER.

In the first place, it must be observed that the bulb of the Thermometer is protected so as to resist the pressure of the ocean, which varies according to depth that of three thousand fathoms being something like three tons pressure on the square inch. The manner of protecting the bulb was invented by Messrs. Negretti and Zambra in 1857, and has been latterly copied by other persons and brought out as a new invention. The manner of protecting the bulb has been described by the late Admiral R. FitzRoy, in the first number of Meteorological Papers, page 55, published July 5th, 1857, as follows:

“Referring to the erroneous readings of all thermometers, consequent on their delicate bulbs being compressed by the great pressure of the ocean, he says:—‘With a view to obviate this failing, Messrs. Negretti and Zambra undertook to make a case for the weak bulbs, which should transmit temperature, but resist pressure. Accordingly a tube of thick glass is sealed outside the delicate bulb, between which and the casing is a space all round, which is nearly filled with mercury. The small space not so filled is a vacuum, into which the mercury can be expanded, or forced by heat or mechanical compression, without doing injury to or even compressing the inner or much more delicate bulb.’”

The construction of this instrument for deep-sea temperatures is as follows:—


Fig. 2.

In shape it is like a syphon with parallel legs, all in one piece and having a continuous communication, as in the annexed figure. The scale of the Thermometer is pivoted on a centre and being attached in a perpendicular position to a simple apparatus (which will be presently described), is lowered to any depth that may be desired. In its descent the Thermometer acts as an ordinary instrument, the mercury rising or falling according to the temperature of the stratum through which it passes; but so soon as the descent ceases, and a reverse motion is given to the line, so as to pull the Thermometer towards the surface, the instrument turns once on its centre, first bulb uppermost, and afterwards bulb downwards. This causes the mercury, which was in the left-hand column, first to pass into the dilated syphon bend at the top, and thence into the right-hand tube, where it remains, indicating on a graduated scale the exact temperature at the time it was turned over. The woodcut, Fig. 1, shows the position of the mercury after the instrument has been thus turned on its centre. A is the bulb; B the outer coating or protecting cylinder; C is the space of rarefied air, which is reduced if the outer casing be compressed; D is a small glass plug on the principle of Negretti and Zambra’s Patent Maximum Thermometer, which cuts off, in the moment of turning, the mercury in the tube from that of the bulb, thereby ensuring that none but the mercury in the tube can be transferred into the indicating column; E is an enlargement made in the bend so as to enable the mercury to pass quickly from one tube to another in revolving; and F is the indicating tube or Thermometer proper. In its action, as soon as the Thermometer is put in motion, and immediately the tube has acquired a slightly oblique position, the mercury breaks off at the point D, runs into the curved and enlarged portion E, and eventually falls into the tube F when this tube resumes its original perpendicular position.


Fig. 3.

The contrivance for turning the Thermometer over may be described as a frame with a vertical propeller; to this frame the instrument is pivoted. On its descent through the water the propeller is lifted out of gear and revolves freely on its axis; but so soon as the instrument is pulled towards the surface the propeller falls into gear and revolves in the contrary direction, turning the Thermometer over once, and then becoming locked and immovable.

Directions for adjusting the Thermometer previous to its being lowered in the Sea.

I. The mercury must all be in the left-hand column.

II. The short peg at the back of the thermometer must be in front of the stop plate S +; in order to effect this, pull the knob which stops the Thermometer, and slightly turn the propeller, to make the Thermometer advance sufficiently to escape the stop plate.

Negretti & Zambra’s Patent Atmospheric Recording Thermometer, Fig. 3, differs from the Deep-sea Thermometer by its not having the double or protected bulb, it not being required for resisting pressures. In this case the instrument is turned over by a simple clock movement, which can be set to any hour it may be desirable; the Thermometer is fixed on the clock, and when the hand arrives at the hour determined upon, and to which the clock is set as in setting an alarum clock, a spring is released and the Thermometer turns over as before described.

Messrs. Negretti and Zambra have arranged a Wet and Dry Bulb Hygrometer upon the same plan.


NEGRETTI & ZAMBRA’S

PRICE LIST

OF

STANDARD METEOROLOGICAL

AND OTHER

PHILOSOPHICAL INSTRUMENTS.

The marginal figures in this List and the numbers of the wood engravings refer to paragraphs in “Negretti & Zambra’s Treatise on Meteorological Instruments.”

   £s.d.
4Standard Barometers, Fortin’s arrangement, as Fig. 3 with mahogany board 880
 Ditto ditto with Millemetre and English scales 990
 Ditto ditto with tube, 0·45 internal diameter and millimetre scale 10100
 Observatory Standard Barometers, extra large tubes and cisterns£2500 3500
 Ditto ditto arranged for observations being taken by the Cathetometer 18180
 Cathetometer, for use with above 2100
9Self Compensating Standard Barometer, Fig. 6 2000
10Standard Barometer, with electrical adjustment 15150
11Pediment Barometers, Fig 7£110 220
 Ditto   ditto     Fig. 8£330 3100
 Ditto   ditto     Fig. 9£4100 5100
 Ditto   ditto     Fig. 10 8100
 Ditto ditto ditto handsome carved mountings, in mahogany, oak, or walnut wood   £8   8   0£10100 12120
14FitzRoy’s Storm or Sea Coast Fishery Barometer, Fig. 12 550
 Ditto   ditto with two verniers 660
 Ditto   ditto mounted in ornamental carved frames, oak, walnut, or mahogany£6100 880
19Marine Barometers, ordinary forms, Figs. 13 and 14         £2   2s.£210s. 330
 Ditto   ditto   Best mounted£55s. 660
20The Board of Trade or Kew Marine Barometer, Fig. 15,        £4   4s.£55s. 660
22Negretti and Zambra’s FitzRoy Marine or Gun Barometer, Fig. 16, with N. and Z.’s
Patent Porcelain Scales, as used in Her Majesty’s Navy
 5100
 Extra Tube for ditto 1150
25Negretti and Zambra’s Farmer’s Barometer or Domestic Weather Glass, Fig. 17 2100
28Negretti and Zambra’s Miner’s Barometers            £1   1s.£22s. 330
31Dial or Wheel Barometers, Figs. 18, 19, 20, 21        £3   3s.£44s. 550
 Ditto   ditto in carved ornamental mountings       £5   10s.   £6   6s.£88s. 10100
 Ditto   ditto rosewood, inlaid with pearl or metal. Made to order, Figs. 22 and 23.
Price varying with size, &c.
37Gay Lussac’s Syphon Tube Mountain Barometer£660 880
32Standard Syphon Barometer, Gay Lussac’s arrangement, Fig. 24 550
38Negretti and Zambra’s Standard Mountain Barometer, with Fortin’s cistern,
with tripod stand and travelling case, Fig. 30
 10100
34Barograph, or Self-registering Barometer, with syphon mercurial tube.
Negretti and Zambra’s improved arrangement, Fig. 26
18180 2500
 Negretti and Zambra’s Self-recording Aneroid Barometer, with Clock 2200
 
 48. ANEROID BAROMETERS.
 Aneroid Barometers, with card dials 4½ inches diameter, best quality. 2100
 Ditto ditto     with silvered metal dial 300
 Ditto ditto     with ditto     and thermometer 3100
 Ditto ditto     ditto with corrected scale, as supplied by Negretti and Zambra to the Royal Navy 550
 Aneroid Barometers, with elegantly-chased dials 440
 Ditto ditto     with raised ring on dial 550
 Ditto ditto     ditto with thermometer 660
 Aneroid Barometer, for altitude measurements with revolving ring, carrying index, range of scale
20,000 feet 4½ inches diameter, with magnifier
 880
 
 POCKET ANEROID BAROMETERS. Fig. 34.
49Pocket Aneroid Barometer, 2¾ inches diameter, with silvered metal scale 330
 Ditto ditto   for measuring altitudes to 10,000 feet compensated for temperature, in leather case 550
 Ditto ditto   ditto    to 20,000 feet, with magnifier 660
 
50WATCH-SIZE ANEROID BAROMETERS in gilt metal cases (see figure 35.)
 Watch-Size Aneroid Barometer, weather range£330 440
 Ditto ditto  of best construction, extra thin, for meteorological observations
or altitude measurements to 10,000 feet
 550
 Ditto ditto  ditto to 20,000 feet, compensated for temperature 660
 Either of the above Watch-size Barometers may be had in Stout Silver Cases at a cost of £2 2s. extra
 Watch-size Aneroid Barometers in Solid Gold, highly-finished cases. £15 15s. to £21.
 Table Stands for Aneroid Barometers of Carved Oak or other woods,
10s. 6d., 25s., 35s., to £5 5s.
 Ships’ Aneroid Barometers, in suitable mountings    £2 10s.    £3 3s.    £5 5s.    £6 6s.
 
47Sympiesometer, for Ship use£330 4100
 Ditto ditto Pocket form, Fig. 32 440
 The Sympiesometer is now rarely used, the Aneroid Barometer being found
equally sensitive and less liable to derangement.
 
56Independent Standard Thermometers, Fig. 36 550
57Standard Thermometers, for Boiling Point Apparatus 1100
 Chemists’ or Brewers’ Standard Reference Thermometers£11s. 220
47Chemical Thermometers, divided on the stem. Fig. 48. 10s.6d. 0150
 Chemical Thermometers, Boxwood Scale          7s. 6d. 10s.6d. 0126
64Thermometers on Boxwood Scales, Fig. 37.       1s.    1s. 6d.    2s. 6d. 3s.6d. 046
 Ditto ditto larger sizes 7s.6d. 0126
 Ditto ditto Engraved glass scales, Fig. 39        15s.    £1 1s.£15s. 1100
 
 POCKET THERMOMETERS, IN VARIOUS MOUNTINGS.
 Fig. 38 10s. 6d. Fig. 40 10s.    6d. 15s.  Fig. 41 5s. 6d.    8s. 6d.    12s. 6d.
63Thermometers of extreme Sensitiveness,                    15s.£110s. 220
 
 Drawing Room or Mantel Thermometers, various mountings, Figs. 42 and 43.
               12s. 6d.    15s.    £1 1s.    £1 10s.
£22s. 2100
 Bracket Window Thermometers, Fig. 46         12s. 6d.     15s.£11s. 1100
 Bath Thermometers, Figs. 44 7s.6d.0150
66Sugar Boiling Thermometers               £1 12s.£22s. 330
67Earth Thermometers, Fig. 51£110s. 220
 Hot Bed Ditto                    12s. 6d.£15s. 1100
68Marine Thermometer, Fig. 52               7s. 6d. 8s.6d. 0106
65Super Heated or Steam Pressure Thermometers, Fig. 74, Figs. 49 and 50   £1 5s.    £1 10s.£22s. 2100
 
 SELF-REGISTERING THERMOMETERS FOR HEAT.
72Negretti and Zambra’s Patent Standard Maximum Self-Registering Thermometer,[21] Fig. 54 110
72Negretti and Zambra’s Patent Maximum Thermometer, on boxwood scale 0106
 Ditto, ditto,  on Negretti and Zambra’s Patent Solid Porcelain or Metal Scales on oak mounting 0126
70Rutherford’s Maximum Thermometer, on boxwood or metal scale, with steel index    5s. 6d. 7s.6d. 0106
71Phillip’s Maximum Thermometer, on boxwood or metal scale, with air index       7s. 6d. 106 0126
 
 SELF-REGISTERING THERMOMETERS FOR COLD.
73Negretti and Zambra’s Standard Minimum Self-Registering Thermometer, Fig. 55 110
73Rutherford’s Minimum Thermometer, on boxwood or metal scale       3s. 6d.    5s. 6d. 7s.6d. 0106
73Rutherford’s Minimum Thermometer, on Negretti and Zambra’s Patent solid porcelain scale 10s.6d. 0126
 Ditto, on Negretti and Zambra’s porcelain or metal scales and oak mounting 0126
74Negretti and Zambra’s Horticultural Self-Registering Thermometer. The scale is made of
stout zinc, enclosing the tube; the figures and divisions are boldly marked for quickly and easily
reading the indications, Fig. 56
 036
 
83Negretti and Zambra’s Patent Solar Radiation Thermometer, Fig. 63 150
84Ditto, ditto, ditto, in vacuo, Fig. 64 1100
 Ditto, ditto, ditto, improved form, with test gauge 220
85Negretti and Zambra’s Terrestrial Radiation Thermometer 150
 Brass Stands for above, Fig. 65 050
76 and 77Negretti and Zambra’s Patent Mercurial Minimum Thermometers£210s. 220
81Maxima and Minima Thermometers, on Sixe’s arrangement, Fig. 62, various forms of mounting
                  12s. 6d.    14s.    21s.
 30s. 220
 Pocket Maxima and Minima Thermometers, Negretti and Zambra’s Patent, in convenient cases£22s. 2100
89Deep Sea Registering Thermometer, with Negretti and Zambra’s improved protected bulb,
in copper cylinder, Fig. 69.
 2100
89[21]Negretti and Zambra’s Improved Deep Sea Thermometer, with vulcanite mountings,
in copper cylinder, with door, small size
 250
90Negretti and Zambra’s Patent Recording Deep Sea Thermometer 10100
91Ditto, ditto, ditto Recording Thermometer 440
92Ditto, ditto, ditto Hygrometer 660
93Improved Boiling Point Mountain Thermometer, or Hypsometric Apparatus, with Tables, Figs. 72 and 73,
in leather case with strap
 550
 Extra Thermometer for Ditto 1100
106Negretti and Zambra’s Standard Wet and Dry Bulb Hygrometer, Fig. 79 220
 Wet and Dry Bulb Hygrometers, various mountings         30s.    25s.    21s. 14s. 0106
 Pocket Hygrometers, in box£22s. 2100
103Daniell’s Hygrometer, Fig. 77 330
104Regnault’s Hygrometer, Fig. 78£310s. 550
 Aspirator for Ditto£115s. 2150
 
110Howard’s Rain Gauge, has a 5-inch copper Funnel, with turned brass rim fitted to a stout stone-ware or
glass bottle, with a graduated glass measure, divided to 100ths of an inch
 0106
 Symons’ Portable Rain Gauge, (5-inch) with graduated glass measure, japanned tin 0106
 Ditto ditto in stout copper 0150
111Glaisher’s Rain Gauge, the receiving surface is 8-inches diameter, of stout japanned metal,
with graduated glass measure, Fig. 84
 110
 Ditto ditto, of stout copper 1100
 Receiving Pots for ditto, extra 2s. and 3s. 6d.
113Rain Gauge, having a receiving surface of 12 inches diameter, and graduated glass gauge tube, divided to
hundredths of an inch, in japanned metal, with brass tap
 2100
 Ditto ditto, Fig. 85, in copper 3100
 Ditto ditto, with sliding rod instead of graduated tube, japanned tin 220
 Rain Gauges, of any form or area made to order, with suitable measuring glasses.
 
123Lind’s Anemometer, Fig. 86 220
125Robinson’s Anemometer, Fig. 87 330
 Ditto ditto, Improved arrangement£410s. 5150
 Ditto ditto, with clutch movement, Fig. 88 6150
 Negretti and Zambra’s Improved Air Meter, of extreme sensitiveness, very portable 440
 Large Air Meters made to order.
127Osler’s Self-Registering Anemometer and Rain Gauge, Fig. 89£84 to 15000
128Berkley’s Anemometers fitted up to order, to suit the Observatory.
131Gold Leaf Electrometer, Fig. 90 110
133Peltier’s Electrometer 440
134Bohnenberger’s Electroscope, Fig. 91 880
135Thompson’s Electrometer, to order
 Lightning Conductors fitted up to order.
142Ozone Cage, Fig. 92 0180
 Ditto ditto, copper 150
146Leslie’s Differential Thermometer, Fig. 93£110s. 220
148Thermometer Stand (Glaisher’s) 330
149Thermometer Screen for Sea use 330
150Anemoscope, or Portable Vane, Fig. 94 250
151Evaporating Dish, Fig. 95 126
157Sea Water Hydrometers, Board of Trade Marine, Figs. 96 and 97 056
158Newman’s Self-Registering Tide Gauge, Fig. 158, fitted to the Building to order From5000
Continue reading